01/02/11 - 300002915-001-E

DTG 130 Eco.NOx

5.4.5

Attaching the label

Affix the label which indicates for which type of gas the boiler is fitted
and set.

5.4.6

Pressure setting and marking of calibrated injectors

(1)

15 °C - 1013 mbar

(a)

Availability in line with the country's sales plan.

5.5 Checks and adjustments after commissioning

Z

Carry out all the checks mentioned in the chapter "Checking

and maintenance" (Page: 29).

5.6 Changing the settings

Z

Control panel instructions

Models DTG ... Eco.NOx

133

(a)

134

135

136

137

138

(a)

139

(a)

Burner

nozzles

Natural gas H/E

GZ50

204B

204B

204B

204B

204B

210B

210B

Natural gas L/LL

GZ410

245B

245B

245B

245B

245B

245B

245B

Propane

140A

140A

140A

140A

140A

140A

140A

H - 13 mbar

225B

225B

225B

225B

225B

225B

225B

GZ350

310B

310B

310B

310B

310B

310B

310B

Manifold

pressure

Natural gas H/E

GZ50

mbar

16

16

16

16

16

15

15

Natural gas L/LL

mbar

12.1

12.1

12.1

12.1

12.1

12.1

12.1

GZ410

mbar

12.5

12.5

12.5

12.5

12.5

12.5

12.5

Propane

mbar

29

29

29

29

29

29

29

H - 13 mbar

mbar

10.2

10.2

10.2

10.2

10.2

9.6

8.4

GZ350

mbar

7

7

7

7

7

6.2

6

Gas flow

rate

Natural gas H/E

GZ50

m

3

/h

(1)

1.42

2.13

2.83

3.52

4.22

4.91

5.60

Natural gas L/LL

m

3

/h

(1)

1.65

2.47

3.29

4.10

4.91

5.71

6.51

GZ410

m

3

/h

(1)

1.71

2.56

3.41

4.25

5.09

5.92

6.75

Propane

Kg/h

1.04

1.56

2.07

2.59

3.10

3.60

4.11

H - 13 mbar

m

3

/h

(1)

1.42

2.13

2.83

3.52

4.22

4.79

5.13

GZ350

m

3

/h

(1)

1.97

2.95

3.92

4.89

5.87

6.50

7.29