10

Application conditions

5.4 Application in gas pumps

DANGER!

Risk of explosion!
Following installation, solenoid coil and valve body form a closed
system. If used in the explosion-risk area, there is a danger of
explosion if the system is opened during operation!

▶ The system must not be disassembled during operation.

▶ The valve body may be repaired by the manufacturer only.
Solenoid valves together with the coil Type 7..-... may be used as
category 2 devices only for the control of gas if there is no air and
no oxygen in the closed system.

▶ Ensure that the closed system contains no air or oxygen or can-

not be penetrated by air or oxygen.

▶ When switching off or starting up the system, ensure that nei-

ther air nor oxygen has penetrated the system.

If the system is used as a category 2 device, only valve bodies
made of metal can ensure the required safety for the control of
gas in gas pumps!

▶ Use only valve bodies made of metal (brass, aluminum or stain-

less steel) for the control of gas in gas pumps with category 2
devices.

5.5 Model with a terminal box

DANGER!

Risk of explosion!

▶ Only specified cables and lines may be used.

▶ The operator must ensure an adequate strain relief.

▶ Lines with an outer diameter from 6 mm to 13 mm may be used.

Observe the maximum thermal load of the installed cables and

lines.

▶ The inserted break-out seal must be adjusted to the diameter of

the cable/line.

▶ The rated cross-section of the cables/line cores must be at

least 0.75 mm² and must not exceed 2.5 mm².

▶ Screws for attaching the cover of the terminal box must be

tightened to a torque of 100 Ncm (±5%).

english

PTB 00 ATEX 2202 X

Advertising