Feldbus module canopen, Canopen, ip20 - overview, Power supply ip20 – Burkert Type 8640 User Manual

Page 62

Advertising
background image

62

FELDBUSmoduleCANopen

13.

FELDBUS MODULE CANOPEN

13.1. CANopen, IP20 - overview

LED Status

Display

Functional earth

Power Supply

Field bus connection

DIP Switches

Figure 39:

Overview FELDBUS module CANopen, IP20

The DIP switches can be operated through the covering film.

13.1.1. Power supply IP20

The 4-pole plug-in connector for the power supply is configured as follows:

Electronics

Inputs

Valves /

Outputs

24 V DC (2)

valves /

outputs

24 V DC (4)

logic

GND (3)

logic

GND (1)

valves /
outputs

Pin 1

Pin 4

1

2 3 4

-

+

-

+

Pin

Valves /

Outputs

Logic

inputs

Figure 40:

Power supply configuration

Figure 41:

Cutaway POWER connection

Pin 2 of the power supply must be supplied with a 4 A medium time-lag fuse; Pin 4 with 1 A.

NOTE!

To ensure electromagnetic compatibility (EMC) connect the screw terminal FE (functional earth) to earth
potential using a short cable (30 cm).