Led status display – Burkert Type 8640 User Manual
Page 66

66
FELDBUSmoduleCANopen
13.4. LED status display
BUS_ERROR (BF)
FAILURE_NUMBER (FN)
U_LOGIK_OK (U
l
)
BUS_RUN (BO)
FAILURE_SELECT (FS)
U_TREIBER_OK (U
0
)
Figure 44:
LED state display (detail)
Abbre-
viation
Colour
Description
Explanation
BO
green
BUS RUN
See CANopen RUN LED
BF
red
BUS ERROR
See CANopen ERROR LED
FS
yellow
FAILURE SELECT
Determines the function of the FN LED:
FS lit up: FN displays fault type
FS not lit up: FN displays failure number
FN
red
FAILURE NUMBER
The number of flash impulses indicates the fault type or the
failure number depending on whether FS is lit up or not
U
l
green
U LOGIC OK
Voltage for logic supply, inputs and bus interface present
U
0
green
U driver OK
Voltage for outputs present
CANopen RUN LED
CAN RUN LED
Device state
Description
Single flash
STOPPED
Field bus module is in STOPPED
state
Flashing on and off
PRE-OPERATIONAL
Field bus module is in
PRE-OPERATIONAL state
ON
OPERATIONAL
Field bus module is in
OPERATIONAL state
english
Type 8640