I

NSTALLATION

16 - 8750



P.CO KV

KV FACT

KVS 2.10

0 000.0

5 003.0

10 004.0

...
95 088.0

100 100.0

At KV FACT, the valve characteristic entered in the
factory, as shown in the Kv-value table, is
activated; alternatively, a user-specific
characteristic may be entered under KV USER;
Note: with the command SETFACT, all manually
changed characteristic values are reset to the
factory settings;
With

further to display of the stored KVs-value

(KVs-value = max. possible flow rate: here 2.10
m³/h); with

further to display of the stored KV-

valve characteristic in %, referred to the KVs-value
(= KV/KVs in [%]); the valve characteristic is
displayed in 5% steps (cf. KV table); a change of
value is only possible with KV USER; after display
of the 100 % point,
with

return to P.CO KV

LEAK D’ACT

LEAK ACT

LEAK MEAS

Taste

gedrückt halten
bei Anzeige
TUNE 5, 4 …1,0.
Es folgen die
Anzeigen
LEAK IN
LEAK PO
LEAK OPN
LEAK PAR und
LEAK END

P.CO LEAK





LEAK CHAR

Deactivate the air leak compensation

Activate the leak compensation

Background: during transport of pourable solids,
there arises at a rotary valve an air leakage
dependent on the pressure. The air flow through
the controller unit is the sum of this leakage and
the air flow of the conveying pipe. Q

FMR

= Q

air leak

+ Q

conv.path

Reading in the air characteristic once with the
conveying pipe closed enables the air leakage to
be compensated during conveying, increasing the
precision of flow control.
The program for automatic registration of the
leakage characteristic is started with P.CO LEAK

LEAK MEAS

Then hold the key

depressed for 5 sec.

NOTE: to break off leakage measurement, press
key

+

simultaneously and select LEAK BRK.