7.4.1 E1 trunk connections

You can use the E-QUE interface card to make E1 connections between Eclipse systems or
between Eclipse systems and compatible third-party equipment.

E1 mode provides 30 channels of G.722 encoded audio available on each of ports 1 and 5,
giving 60 channels per card.

The E1 specifications are:

• HDB3 Encoding.

• Long Haul Receive Signal Level.

• E1 120 Ohm Transmit Pulse Amplitude.

• Balanced.

• 120 Ohm Line Impedance.

• No Signaling.

• G.722 64 kbit/s Audio Encoding.

• Tx Clock locally generated.

• Rx Clock Line Recovered.

Figure 29: Matrix to Matrix direct E1 Trunking shows E1 trunking using a direct
connection between the matrices using a CAT5 crossover cable. The E-QUE interface
should be set to E1 Direct in EHX hardware setup.

76

Eclipse HX Matrix Frame Installation Guide