The pinout for the CAT5 cable to connect an AES-6-RJ to a V-Series panel AES-3 interface
is given in the table below.

Pin

Wire color

Description / function

1

White

/

Orange

not used

2

Orange

not used

3

White

/

Green

Rx (+)

4

Blue

Tx (+)

5

White

/

Blue

Tx (-)

6

Green

Rx (-)

7

White

/

Brown

not used

8

Brow

n

not used

Table 35: AES-6 to panel wiring (CAT5 cable)

The AES-3 interface RJ45 connection is capable of operation with up to 200m of screened
Cat5e cabling of 110 ohm +/- 10 ohm impedance, with 24 AWG cores.

If 26AWG or smaller cable is used the maximum cable run may be severely reduced.

The specification for the coaxial cable required to connect V-Series panels AES-3 interfaces
to an AES-6-CX card is given below.

Characteristic

Requirement

Nominal impedance

75 Ohm

Insulation

solid polyethylene

Screen

double braided copper

Capacitance

68pF/m or better

Equivalents

BBC PSF 1/3M
BICC TM 3304
Brand Rex GT 851

Table 36: Coaxial cable specification

This type of cable will allow up to 500 metres of cable run between the AES-6-CX interface
and the panel at the standard 48K sample rate.