1/2"

1/2"

SAFETY CATCH ROLLERS

Install catch rollers with safety covers on the side of a post or wall with a

minimal distance of half an inch between the rollers and gate.

DO NOT use a gate catch post.
Because the coasting distance may vary due to changes in temperature, it is

NOT recommended to install a stop or catch post in front of the gates path.

To do so will cause the gate to hit the post in certain instances.

1
2

2

1

Outside Property

Inside Property

Inside Safety

Loop

Gate Rail Stop

Gate Rail Stop

Gate Rail Stop

Gate Rail Stop

SITE PREPARATION

BEFORE installing the operator, be sure to check the following:
• Gate is constructed and installed according to ASTM F2200 standards

• Gate fits specifications of operator

• National and local building codes

• Earth ground rod

• UL approved conduit for low and high voltage

• Mounting considerations post or pad

• Operator placement
SAFETY CONSIDERATIONS:
• Warning signs

• Entrapment devices such as loops, contact sensors and non-contact sensors

INSTALLATION

» SITE PREPARATION + TYPES OF INSTALLATIONS

REAR INSTALLATION
The illustration is an example of a rear installation.

TYPES OF INSTALLATIONS

STANDARD INSTALLATION
The illustration is an example of a standard installation.