Required safety protection devices, Safety – Controlled Products Systems Group RSL12V User Manual

Page 6

Advertising
background image

Outside Safety

Loop

Inside Safety

Loop

Outside Property

Inside Property

Entrapment Danger

Safety Danger

Outside Safety

Loop

Inside Safety

Loop

Outside Property

Inside Property

Safety Danger

Edge sensor for close cycle

Edge sensor

for close cycle

Edge sensor for open cycle

Edge sensor for open cycle

Edge sensor for open cycle

Install photoelectric sensors and edge sensors to protect against any entrapment or

safety conditions encountered in your gate application.
The safety loops allow the gate to stay open when vehicles are obstructing the gate

path. Suggested for vehicles 14 feet (4.27 m) or longer. Safety loops are not

required safety devices but are recommended.

NON-CONTACT SENSORS

Use photoelectric sensor model 50-220.

CONTACT SENSORS (EDGE SENSORS)

Use edge sensor models G65MG0204, G65MG0205, G65MGR205, or G65MGS205

(2-wire, non-monitored).

To prevent SERIOUS INJURY or DEATH from a moving gate:
• Entrapment protection devices MUST be installed to protect anyone who may

come near a moving gate.

• Locate entrapment protection devices to protect in BOTH the open and close

gate cycles.

• Locate entrapment protection devices to protect between moving gate and

RIGID objects, such as posts or walls.

SAFETY

» REQUIRED SAFETY PROTECTION DEVICES

4'

4'

4'

4'

5

Advertising