Power wiring, Wiring – Controlled Products Systems Group RSL12V User Manual

Page 13

Advertising
background image

POWER WIRE (STRANDED COPPER WIRE)

500 feet or less

500 feet to 1000 feet

Wire Gauge 14 - 500 feet (152 m)

Wire Gauge 12 - 1000 feet (305 m)

Transformer 13.5 Vac

Transformer 14.5 Vac

POWER WIRING

This operator can be powered by the internal receptacle, an external

receptacle or a solar panel (not provided).
INTERNAL RECEPTACLE

CHGR
OVLD

CTRL

AC PWR
/SOLAR

1

2

3

4

NOTE:

All power wiring should be on a dedicated circuit, calculated using NEC

guidelines. National and local electrical codes must be reviewed for suitability of wire

installation.

Remove the access panel.

Connect AC power to the operator:
• Connect the green wire to the ground screw in the access panel.
• Connect the black and white wires together with wire nuts.

HEATER WIRING:
NOTE:

If your operator comes with a heater it will have to be wired. The heater may

be wired to the internal receptacle or a separate junction box.
If wiring the heater to the internal receptacle, remove the knockout in the chassis

behind the internal receptacle (refer to illustration). Thread the heater wires through

the knockout and connect the heater wires to the power wires of the operator with

wire nuts (green to green, black to black, and white to white).

Replace the access panel.

Connect the wires from the transformer to the AC PWR/SOLAR terminal located

on the control board.

Plug the transformer into the internal receptacle.

EXTERNAL RECEPTACLE

NOTE:

All power wiring should be on a dedicated circuit, calculated using NEC

guidelines. National and local electrical codes must be reviewed for suitability of wire

installation. The transformer must be located in a dry location that is protected from

weather conditions, such as inside the house or garage.

Run low voltage wire between the transformer and the operator.

Connect the wires from the transformer to the AC PWR/SOLAR terminal located

on the control board.

Plug the transformer into the external receptacle.

5

CHGR
OVLD

CTRL

AC PWR
/SOLAR

1

2

3

14.5

Vac COM

13.5

Vac

WIRING

» POWER WIRING

Knockout for

Heater Wires

Operator

Power Wires

Heater

Wires

1

2

3

4

5

120 VAC POWER WIRE (STRANDED COPPER WIRE)

Wire Gauge 16 - 100 feet (30 m)

Wire Gauge 10 - 1000 feet (305 m)

1

2

3

12

Advertising