Force adjustment, Test, 3adjustment – Controlled Products Systems Group RSL12V User Manual

Page 21: Force adjustment + test

Advertising
background image

FORCE

OFF

MAX

SINGLE BUTTON

Outside

Pr

oper

ty

Inside

Pr

oper

ty

3

ADJUSTMENT

»

FORCE ADJUSTMENT + TEST

FORCE ADJUSTMENT

The operator is equipped with an obstruction sensing feature. If the gate encounters

an obstruction the operator will automatically reverse direction for a short time and

stop. Based on the length and weight of the gate it may be necessary to make force

adjustments. The force adjustment should be high enough that the gate will not

reverse by itself and not cause nuisance interruptions but low enough to prevent

serious injury to a person.
TO ADJUST THE FORCE

Use the SINGLE BUTTON to open and close the gate.

If the gate stops or reverses before reaching the fully open or closed position

increase the force by turning the force control slightly. On dual gate

applications the force will require a higher setting because it is affecting two

motors instead of one.

Run operator through a complete cycle.

NOTE: Weather conditions can affect the gate movement, so seasonal adjustment

may be required. The force control is factory set to the mid-position.

1
2

3

2

The basic installation is complete. Entrapment

protection devices are required (see Entrapment

Protection Devices in the Additional Features section).

TEST

After any adjustments are made, test the operator:

Use the SINGLE BUTTON to open and close the gate.

Test the limits by making sure the gate is stopping at the OPEN and CLOSE

limits.

Test the force by making sure the gate will stop and reverse direction for a

short time on contact with an obstruction.

1

2
3

Outside

Pr

oper

ty

Inside

Pr

oper

ty

2

3

Outside

Pr

oper

ty

Inside

Pr

oper

ty

1

SINGLE BUTTON

1

20

Advertising
This manual is related to the following products: