Single gate right-hand side, 5adjustment, Learn limits – Controlled Products Systems Group RSL12V User Manual

Page 18

Advertising
background image

Outside

Pr

oper

ty

Inside

Pr

oper

ty

Outside

Pr

oper

ty

Inside

Pr

oper

ty

Outside

Pr

oper

ty

Inside

Pr

oper

ty

GATE 2

SET

CLOSE

LIMIT

GATE 1

G

SET

CLOSE

LIMIT

GATE

A

SET

OPEN

LIMIT

N

N

LEARN
LIMITS

SET

CLOSE

DIAGNOSTIC

GATE 1

SET

CLOSE

DIAGNOSTIC

GATE 1

SET

OPEN

LIMIT

SET

CLOSE

LIMIT

SET

OPEN

LIMIT

SINGLE GATE RIGHT-HAND SIDE

Close the gate.

Press and release the LEARN LIMITS button. The SET OPEN LIMIT LED will blink.

PROGRAM OPEN

Press and hold the GATE 1 left button to move the gate to the desired OPEN

position. When the gate is in the desired position, release the button.

NOTE: The GATE 1 right and left buttons can be used to jog the gate back and

forth as needed.

When gate is in the desired OPEN position, press and release the

LEARN LIMITS button. The control board will beep and the SET CLOSE LIMITS

LED will blink.

PROGRAM CLOSE

Press and hold the GATE 1 right button to move the gate to the desired CLOSED

position. When the gate is in the desired position, release the button.

NOTE: The GATE 1 right and left buttons can be used to jog the gate back and

forth as needed.

When gate is in the desired CLOSED position, press and release the

LEARN LIMITS button. The control board will beep and the SET CLOSE LIMITS

LED will stop blinking.

Programming is now complete. If the SET OPEN LIMIT LED continues to blink, repeat

programming. If the problem continues, see below.
Test the limits by pressing the SINGLE BUTTON to open and close the gate.

4

"BEEP"

6

"BEEP"

LEARN LIMITS Button

LEARN LIMITS Button

GATE 1 Left Button

3

GATE 1 Right Button

5

ADJUSTMENT

» LEARN LIMITS

IF THE LIMITS WILL NOT PROGRAM

Disconnect the operator by pressing the reset switch to RESET/DISCONNECT.

Manually close the gate.

Remove the learn limit cover and move the learn limit nut to the center

position.

Press the reset switch to NORMAL OPERATION.

Program the limits again.

1

2

3

4

LEARN LIMITS Button

2

1

Learn Limit Cover

Learn Limit Nut

Learn Limit Switch

3

4

6

5

2