Additional features, Timer-to-close, Auto open jumper – Controlled Products Systems Group RSL12V User Manual

Page 23: Heater, Party mode

Advertising
background image

TIMER TO
CLOSE

OFF

MAX

ADDITIONAL FEATURES

» TIMER-TO-CLOSE + AUTO OPEN JUMPER + HEATER + PARTY MODE

HEATER

The operator may have a heater installed, depending on the model purchased. The

heater must be powered by 120 Vac ONLY. If the heater switch is left in the “ON”

position, the heater will turn on and off automatically when needed.
The operator battery can be set on the bracket shelf underneath the heater. Make

sure the battery terminals DO NOT make contact with the operator

chassis as this will short the control board. Disconnect the batteries

BEFORE servicing the operator.

TIMER-TO-CLOSE (TTC)

The TIMER-TO-CLOSE feature can be set to automatically close the gate after a

specified time period. The TTC is factory set to OFF.
If the TTC is set to the OFF position, then the gate will remain open until the operator

receives another command from a remote control or the SINGLE BUTTON.
TO SET THE TIMER-TO-CLOSE

Rotate the TIMER-TO-CLOSE dial to the desired setting. The range is 0 to 180

seconds, 0 seconds is OFF.

NOTE: Any remote control or SINGLE BUTTON command on the control board prior

to the TTC expiring will close the gate. The TTC is reset by any signals from the loops,

close edges and close photoelectric sensors.

PARTY MODE

If the Timer-to-Close feature is enabled and you would like the gate to remain open,

open the gate fully, then toggle the reset switch. The next command given by a

LiftMaster remote control or SINGLE BUTTON on the control board will close the gate

and return the operator to normal operation.
NOTE: To keep the gate open indefinitely, press the reset switch to

RESET/DISCONNECT. To resume normal operation press the reset switch to NORMAL

OPERATION. If an alternative radio receiver is wired to the operator, the receiver

must be wired to the SINGLE BUTTON and CTRL PWR inputs. Refer to page 21.

1

AUTO OPEN JUMPER

The factory default position is OFF. If the AUTO OPEN jumper is moved to the “ON”

position, when the operator reaches a low battery voltage threshold (11.5 Vdc) it will

automatically open the gate and hold it in the open position. When the operator

reaches normal battery voltage (12 Vdc or above) the operator will close the gate

when a command is given by either a remote control or the SINGLE BUTTON.

1

1

NORMAL

OPERATION

RESET/

DISCONNECT

22

Advertising
This manual is related to the following products: