Stop, 6 rs-232 speed setting, 7 switch input feature – DoorKing 1833 PC Programmable User Manual

Page 30: 8 elevator control feature, 9 single or multiple systems

Advertising
background image

1835-065-E-7-13

28

1. Press and enter your four-digit MASTER CODE (beep).

2. Enter for 9600 baud rate or for 19200 baud rate, then press (beep).

3. Press together to end this programming sequence (beeeeeep).

The following programming sequence sets an optional faster RS-232 speed. This feature is available on Rev M boards or higher
and the Remote Account Manager Software, Version 6.3.b, must be used.
Factory setting = 0 (9600 baud rate)

3.2.6 RS-232 Speed Setting

??

??

??

??

55

JKL

JKL

88

TUV

TUV

00

OPER

OPER

11

SP

SP

00

OPER

OPER

The following programming sequence sets the switch input (main terminals #4 and #6) to either activate a relay(s) or call the
phone number programmed in directory code 0, 00, 000 or 0000. Refer to section 3.3.4 to determine which relay(s) will activate
when the switch input is activated. This feature is available on Rev K boards or higher.
Factory setting = 0 (switch input activates relay)

3.2.7 Switch Input Feature

1. Press and enter your four-digit MASTER CODE (beep).

The LCD display on the 1834, 1835 and 1837 systems will read: KEY IN DIAL? 0=N 1=Y

2. Enter for YES (the switch input will dial a phone number) or for NO (the switch input will activate the relay), then

press (beep).

3. Press together to end this programming sequence (beeeeeep).

??

??

??

??

88

TUV

TUV

11

SP

SP

00

OPER

OPER

This new elevator feature authorizes floor access to the Floor Level identified in the Resident Screen in the software program AND
to the floor(s) level identified in the Security Level screen. If this feature is turned off, access will be granted only the floor
identified in the user’s security level. This feature is available on Rev K boards or higher. This feature is NOT available for the 1834.
Factory setting = 1 (new elevator function is turned ON)

3.2.8 Elevator Control Feature

1. Press and enter your four-digit MASTER CODE (beep).

The LCD display on the 1835 and 1837 systems will read: NEW EL FUNC? 0=N 1=Y

2. Enter for YES (access is authorized to both the floor identified in the resident screen and to the floor(s) identified

in the user’s security level) OR for NO (access is authorized only to the floor(s) identified in the security level

screen), then press (beep).

3. Press together to end this programming sequence (beeeeeep).

??

??

??

??

55

JKL

JKL

77

PQRS

PQRS

00

OPER

OPER

11

SP

SP

11

SP

SP

00

OPER

OPER

00

OPER

OPER

This program sequence sets the telephone entry system to operate as a single unit on the phone line, or to share the phone line
with other units. If multiple systems are sharing the same phone line, then each one must be set as a "multiple system" and
each must have a unique master code.
Factory setting = Single System.

3.2.9 Single or Multiple Systems

1. Press and enter your four-digit MASTER CODE (beep).

2. Press (beep) for a single system, OR (beep) for multiple systems.

3. Press together to end this programming sequence (beeeeeep).

??

??

??

??

44

GHI

GHI

00

OPER

OPER

00

OPER

OPER

11

SP

SP

00

OPER

OPER

STOP!!

If the telephone entry system is to be programmed from a PC, NO other programming is required at the system

itself. Refer to the Remote Account Manager for Windows Software help screens for additional programming information.
Continue with the remaining sections in this chapter if the telephone entry system will be programmed by any other method. If
the factory setting matches your need, there is no reason to reprogram that section.
Remember that advanced features like relay hold open time zones, security levels, and elevator control functions can ONLY be
programmed from the Remote Account Manager Software. If any of these advanced features are being used, DO NOT proceed
with any other programming steps in this manual.