Impulse 463E User Manual

Page 24

Advertising
background image

© Sealevel Systems, Inc.

- 21 -

SeaI/O User Manual

SeaI/O-470 Jumper and Dipswitch Settings Instructions

The SeaI/O-470 module ships factory configured with the D/A outputs set for 0-10V
and current loop mode on the A/D inputs disabled. If you need to enable current loop
mode or set the D/A outputs to 0-5V, you will need to open the enclosure and access
the jumpers (shown on the next page).

NOTE:

Do not perform these instructions with the power connected. Be
sure to follow proper ESD procedures by grounding yourself and the
SeaI/O module.

What you will need:

SeaI/O-470 module

Phillips head screwdriver

Slotted screwdriver


Step 1
Remove the terminal block from the left side and
then remove the two black screws from each side
of the module as shown in the image.

Step 2
On the front right side of the module, wedge a
slotted screwdriver between the top and bottom
halves as shown. Pry upwards – a pem in the top
half must clear the metal lip in the bottom half of
the enclosure.
Jumpers and dipswitch locations are shown on the
following page.


Advertising