Seai/o pass-through connector, Wiring options – Impulse 463E User Manual

Page 27

Advertising
background image

© Sealevel Systems, Inc.

- 24 -

SeaI/O User Manual

Wiring Options

SeaI/O Pass-Through Connector

All SeaI/O modules include two RS-485 pass-through connectors on the left side of
the unit that are internally connected to the same pins on the screw terminals. This
offers two convenient options for adding additional expansion modules.
For connecting several SeaI/O modules together in a “stack”, all N-series expansion
modules ship with an expansion and strap kit (item# KT122) that includes four metal
straps, four #4-40 screws, and a 5” RJ45 RS-485 interconnect cable (item# CA239).
The metal straps allow you to securely connect multiple SeaI/O modules together.
The interconnect cable can be used to connect SeaI/O modules together via the RJ45
pass-through connectors, providing an easy method to cascade RS-485 signals and
power from one module to the next.
For expansion modules that are less than ten feet from a base unit, a standard RJ45
CAT5 patch cable may be used. For SeaI/O modules greater than ten feet apart, use
twisted-pair cable connecting the data lines to the screw terminals instead. If RJ45
connectors are preferred, be sure to connect only the data lines (pins 4 & 5).

NOTE:

Modules greater than ten feet apart must have separate power
supplies. Refer to the Power Options section of this manual for
recommendations.