A functional description of each method in the class, including the possible return
values, is provided. All return values less than zero are standard error codes listed
and defined in the standard C library header file <errno.h>. In the following, with the
Object-Oriented model, the Visual C++ DLL is designed as a single class. This class
has the following model:

Open

CSeaMaxW32::Open( unsigned char* filename )

Description

Opens the specified resource. The filename parameter can be one
of two different types, Modbus RTU or Modbus TCP.

To specify a Modbus RTU connection (used for all non-Ethernet
enabled modules) the string “sealevel_rtu://COMx” sh
ould be
used, where x is a valid COM port number.

To specify a Modbus TCP connection (used only for Ethernet
enabled modules) the string “sealevel_tcp://x.x.x.x” sh
ould be
used, where x’s represent the valid IP address of the module to be
accessed.

Parameters

unsigned char* filename

Return Codes

-38

ENAMETOOLONG

The length of the filename is
greater than 256 characters.

-22

EINVAL

The specified protocol is invalid,
or, the module could not be
contacted.

-9

EBADF

The specified location is invalid

0

Success

Close

CSeaMaxW32::Close( )

Description

Closes a previously opened SeaIO module resource.

Parameters

None

Return Codes

0

Success