- 52 -

SeaI/O User Manual

D/A Outputs Tab

The “D/A Outputs” tab is useful for manually setting the digital to analog output
voltages. A preliminary diagnostics utility (see following page) has been provided to
verify proper hardware functionality.
The D/A outputs of the SeaI/O-470 are factory set for 0-10V. To configure the D/A
outputs for 0-5V, you will need to open the enclosure and set the correct jumpers.
Refer to the Hardware Configuration section of this manual for instructions on
opening the enclosure and accessing the correct jumpers.
To adjust a particular channel’s output voltage, drag the slider until the desired
voltage is displayed in the window on the right side. Also, you may type the desired
voltage directly into the voltage display and press the ‘Enter’ key.


NOTE:

The output voltage will not change until the ‘Enter’ key is pressed
or you have clicked on the window anywhere outside of the field.