9 steam mass, Steam mass steam mass illustration, Calculations – Liquid Controls SP4000 User Manual

Page 24: Mass flow mass flow = volume flow • density (t, p)

Advertising
background image

21

SP4000 Flow Computer

3.9 Steam Mass

Measurements:
A flowmeter measures the actual volume flow in a steam line. A temperature and/or
pressure sensor is installed to measure temperature and/or pressure.

Calculations:
• Density and mass flow are calculated using the steam tables stored in the flow

computer.

• Saturated steam requires either a pressure or temperature measurement with the

other variable calculated using the saturated steam curve.

• Optional steam trap monitoring using Compensation Input 1.

Input Variables:

Superheated Steam: Flow, temperature and pressure
Saturated Steam: Flow, temperature or pressure

Output Results:
• Display Results

Mass or Volume Flow Rate, Resettable Total, Non-Resettable Total,
Temperature, Pressure, Density (optional: peak demand, demand last hour,
time/date stamp)

• Analog Output

Mass or Volume Flow Rate, Temperature, Pressure Density, Peak Demand,
Demand Last Hour

• Pulse Output

Mass or Volume Total

• Relay Outputs

Mass or Volume Flow Rate , Total, Pressure, Temperature, Alarms, Peak
Demand, Demand Last Hour

Applications:
Monitoring mass flow and total of steam. Flow alarms are provided via relays and
datalogging is available via analog (4-20mA) and serial outputs.

STEAM MASS

Steam Mass
Illustration

714

Flowmeter

Condulet

Temperature

Transmitter

PRINT

5

0

TIME

CLEAR

MENU

ENTER

HELP

TEMP

4

PRE 1

3

RATE

2

TOTAL

1

GRAND

6

SCROLL

7

PRE 2

8

DENS

9

Pressure

Transmitter

Mass Flow

Mass Flow = volume flow • density (T, p)

Calculations

Advertising