91

SP4000 Flow Computer

Two counters contain the number of times the calibration and/or
configuration parameters have been changed. Changes in important
calibration and configuration data are registered and displayed
("electronic stamping"). These counters advance automatically.
These counters cannot be reset so that unauthorized changes can
be identified.

Example:

CAL 015 CFG 076

Display:

CAL 015 CFG 076
EXAMINE AUDIT TRAIL

A list of errors that have occurred can be viewed and cleared.

Selection:

VIEW? NO
VIEW? YES

If "YES" is selected the error log can be viewed and errors
individually cleared (if editing enabled with Service Code).

Display:

CLEAR? NO
POWER FAILURE

Display the software version of the flow computer. (Contact local
agent for upgrade information)

Example:

02.00.14

Display:

02.00.14
SOFTWARE VERSION

Display the hardware version of the flow computer. (Contact local
agent for upgrade information)

Example:

01.00.01

Display:

01.00.01
HARDWARE VERSION

EXAMINE AUDIT
TRAIL

ERROR LOG

SOFTWARE
VERSION

HARDWARE
VERSION

SERVICE & ANALYSIS