12.0 Resin Gel Alarm – RGA
The RGA unit is set to operate only when injection takes place. On injection start both the
green light and yellow light illuminate.
If injection is either stopped or the machine stops pumping (stalled) for more than 60 -120
seconds the Top green light will change colour to Red flashing mode and an audible alarm
will sound.
If injection is restarted then the Red light changes back to Green and the alarm warning
stops.
At the end of injection when the counter or the operator stops the injection and proceeds to
flush the machine head the Red light will continue to flash for 30 seconds (without the
audible warning) and the RGA unit will then revert to sleep mode.
If the operator switches off the flush command earlier than 30 seconds the audible warning
will start again with the red light still on demanding that a full 30 seconds of flush and head
mixer air dry out is commanded.