13.0 SSB Auto Machine Doctor
This table provides typical fault conditions their possible causes and remedies
Fault
symptom
Possible cause
Remedies
Machine fails to
start on
recirculation or
injection
command
1. Air supply too low
Ensure air supply at least 6 bar
(90psi)
2. Pump speed set too
low
Set at least to 1 bar and above
3. MPG set too low
Set MPG pressure higher
ON injection
command
( when green
button is
pressed)
4. Auto head valves
NOT reached open
inject position and thus
not providing start signal
to machine
Check both Resin and catalyst head
valve have moved to open position.
Observe Metal pin at pneumatic
actuator has moved out.. Approx 8
mm for Resin valve and 5 mm for
catalyst valve. If not then increase
shop air pressure or service the
valve at fault.
5. PDC Counter not
reset correctly or set at
zero
Press reset firmly or set at least a
count of 5
6. Catalyst over
pressure valve operated
- Either the NRV4 has a
blockage OR the head
mixer is blocked.
Check Catalyst Over pressure valve
is NOT leaking small air volume
from brass body end cap
If this valve has an air leak then it
has triggered the machine to stop.
Investigate why the valve has
triggered as it indicates the catalyst
has found significant blockage.
Inspect NRV8 for signs of blockage
5. Catalyst head valve
has not fully opened
when commanded by
injection command
Check both the resin auto valve and
the catalyst auto valve have opened
.The Resin valve must fully open to
signal the catalyst valve to open.
Both should indicate their
respective open positions by the