Magnum Venus Plastech PATRIOT SSB Auto User Manual

Page 37

Advertising
background image

Patriot SSB Auto Instructions Issue 05 30/06//08

Page 37 of 43

The internal 9 vdc battery is accessed by sliding out the front battery draw. Under normal
use the standard PP3 9vdc battery should last for more than two weeks. If the battery has
insufficient volts the lower yellow light will flash. If this condition is observed immediately
renew the battery.


Gel time Changes

If the gel time is to be reset to another time interval it is necessary to access the rear of the
RGA enclosure. Here will be found a small blue adjuster wheel on the box rear face. By
rotational switching clockwise the time will be increased and decreased if rotated anti
clockwise

As previously stated, the time before the alarm is activated can be selected by the user,
based on the resin system being utilised. On the SSB machine model it is necessary to open
the control fascia to access this RGA rear position. This is achieved by setting the rotary
switch, located on the rear of the RGA, to the position for the required time as specified in
the following table.

SWITCH SETTING

Pump inactivity time (minutes)

0

0.25

1

0.5

2

1

3

2

4

3

5

4

6

5

7

6

8

7

9

8

A

9

B

10






RGA Alarm time set switch.

Use small screwdriver to

adjust. DO NOT force beyond

stops

Advertising