Patriot SSB Auto Instructions Issue 05 30/06//08

Page 5 of 43

To set resin outlet line
pressure limit, adjust
to at least 0.5 bar
(7 psi)





To flush head, Pull
OUT for at least 30
seconds.


Resin Gel Alarm. To
activate – install 9 vdc
battery. See

Adjust air pressure
to pump motor to at
least 1 bar (15 psi)



To recirculate the
operate this control
to ON ( turn
clockwise ¼ turn)



To inject Press this
button IN



To adjust Catalyst
ratio turn to right to
increase ratio. Turn
to left to decrease
ratio

+

Note the PDC Counter can
only be adjusted when PDC
white button is continuously
pressed whilst pressing each
counter button to select
predetermined count number.

Note. If counter is set to zero
then it is NOT possible to press
green start

Counter reset

Count set