Machine overview – Minuteman E Ride 28_32 Rider Scrubber User Manual

Page 22

Advertising
background image

22

Machine Overview

1.12

Circuit Breakers

The circuit breakers are located on the front
panel under the seat. The 6-amp breaker
(CB2) protects all auxiliary circuits on the
machine. The 100-amp breaker (CB1) pro-
tects the main system circuit (TRIO control-
ler). On the cylindrical models only - The two
30-amp breakers
(CB3 & CB4) protect the
cylindrical brush deck motors. Each main
component is individually protected with an

internal breaker built-in the

controller. (See fault code table) and can be
reset by turning the key switch off a few sec-
onds and then on again. The 100 amp circuit
breaker can also be used as a main power
disconnect, this should be used only in case
of emergency. When tripped the breaker re-
moves power from the main controller and all
auxiliary power circuits.

1.13

Battery Compartment

The battery compartment is located on the
rear of the machine under the recovery tank.
Unlatching the two safety latches on the side
of the machine enables the operator to tilt
the recovery tank and access the batteries
for servicing and maintenance (make sure
recovery tank has been drained before tilt-
ing). The battery compartment contains six,
6-volt batteries connected in series. Connect
the batteries according to the battery con-
nection diagram (see diagram). The recom-
mended batteries are 235Ah (Minuteman
P.N. 956740). The two batteries positioned in
the center are offset and held in position by
two steel spacers. These spacers keep the
batteries from sliding inside the battery com-
partment during machine use and prevent
undesired stresses in the battery cables. Be
sure to replace these spacers whenever re-
installing batteries.

Advertising