9 connecting the drive units, Rqqhfwlqj wkh gulyh xqlwv – Diamond Products FZ-4S User Manual

Page 28

Advertising
background image

Connecting the drive units

FZ-4S

Page 28

FZ-4S_e_0205.fm



&RQQHFWLQJ WKH GULYH XQLWV

)XQGDPHQWDOV

z

Clean the couplings regularly

z

Always switch off the drive unit and relieve
the pressure in the hoses before handling
the wall saw

z

If the hoses cannot be connected easily,
they are under pressure

(Release pressure in the hose)

5HOHDVLQJ SUHVVXUH LQ WKH KRVH

1.

+RVHV FRXSOHG WR WKH GULYH XQLW

(see drive unit operating instructions)

2.

+RVHV WKDW DUH QRW FRXSOHG

Put the supplied pressure relief valve on the coupling

and screw it in

&RQQHFW KRVHV

The following hose connections must be

established:

z

Connect the hose couplings with the angle
pieces to the wall saw head

z

Connect the straight hose couplings to the
drive unit

z

Push the hose coupling onto its counterpart
until you hear it “click”

z

Twist the locking ring of the coupling

Never connect or disconnect
hoses when the drive unit is
running.

If the unit is running or if the
hoses are under pressure, a
stationary saw blade can still
suddenly rotate and seriously
injure someone. It is therefore
essential to closely follow the
instructions below.

Connect together both ends of any hoses,
which are not used, so that they are kept
clean and are protected.

:DOO VDZLQJ V\VWHP

'ULYH XQLW

Saw motor

Main circuit

Swivelling motor

Feed circuit

Feed motor

Feed circuit

Water connection

Water connection

Never use force to connect the couplings

Advertising