Troubleshooting fz-4s, Dxow 3rvvleoh fdxvh 6roxwlrq – Diamond Products FZ-4S User Manual

Page 36

Advertising
background image

Troubleshooting

FZ-4S

Page 36

FZ-4S_e_0205.fm

Main pressure fluctuates wildly

Speed too low

Mount correct saw motor according to
motor table

Saw motor worn out

Exchange motor

Defective drive unit

Check drive unit

Wrong or defective feed motor

Exchange motor

Blade does not rotate when main circuit
is switched on

Saw blade jams

Lift saw blade from cut slightly

Defective drive unit

Check drive unit

For safety reasons the main shaft of the
wall saw head is immobilised if no blade
seat flange is mounted on the hub

Mount saw blade correctly with blade
seat flange on the hub

Incorrectly coupled

Check couplings

Saw motor heavily fouled by oil

Defective saw motor shaft sealing ring

Exchange shaft sealing ring

Motor size 3 leak oil connection
incorrectly coupled

Couple leak oil connection correctly

Leaky seals or couplings (FD)

Exchange seals or couplings, contact
HYDROSTRESS after sales service

Coupling leaks

Defective seal

Replace seal

Defective coupling

Replace coupling

No water on saw blade

Water valve shut off

Open water valve.

Water hose incorrectly coupled

Couple water hose, locking ring must
slide forwards

Water pressure too low

Water pressure: min. 1 bar

Water supply interrupted

Check the water supply

Pipes frozen

Thaw pipes, contact HYDROSTRESS
after sales service

Defective seal between shaft and blade
hub

Exchange seal, contact
HYDROSTRESS after sales service

Sawing power is inadequate, despite
correctly selected saw motor

Defective saw motor

Replace saw motor

Defective feed motor

Replace feed motor

Defective drive unit

Check drive unit

)DXOW

3RVVLEOH FDXVH

6ROXWLRQ

Advertising