7 rs-485 wiring, Device board terminals – DoorKing 1838 Telephone Access Plus User Manual

Page 14

Advertising
background image

1.7 RS-485

Wiring

Device 1

Address 003

Device 2

Address 004

3

5

2

6

3

5

2

6

1

1

6

12 – 24 Volt, AC or DC power. Do not power
Device board(s) from 1838 Unit. They must be
supplied with their own power source as shown .

Lock power. Do not power magnetic locks or electric strikes from the device circuit
board power source. Locks must be powered from their own source .

Magnetic locks are wired to the Normally Closed relay
contacts. Electric strikes are wired to the Normally
Open relay contacts.

SW 5 is in the OFF position for middle units, and in the ON position for end units. If
terminals 6, 7 & 8 have two wires connected to them, the SW 5 must be OFF. If terminals 6,
7 & 8 have only a single wire connected, the SW 5 must be ON.

7

7

Maximum distance from end to end is 4000 feet in a Daisy Chain format as shown in the
diagram at right.

Exit

Note RS485 ‘Daisy Chain’ wiring. Controller does
not need to be on the end.

ON

Address 004

End Units
SW 5 ON

Address 003

OFF

Middle Units

SW 5 OFF

ON

Address 005

End Units

SW 5 ON

ON

Address 005

End Units

SW 5 ON

OFF

Address 004

Middle Units

SW 5 OFF

Address 003

OFF

Middle Units

SW 5 OFF

Access Plus

Controller

ON

Address 005

End Units

SW 5 ON

OFF

Address 004

Middle Units

SW 5 OFF

Address 003

OFF

Middle Units

SW 5 OFF

Correct – 4000 Ft. Max.

Correct – 4000 Ft. Max.

A switch closure across the device board terminals 9 & 10 will activate the device
(card reader, keypad, RF receiver) relay for its programmed strike time.

4

4

SW

3

SW2

SW

4

11

12

13

16 15 14

17

1

2

3

4

5

6

7

8

9

10

OFF

SW5

The wires connected from the 1838 RS-485 board
(terminals1 & 2) to the Device boards (terminals 8 & 7)
MUST be twisted. We recommend that you use
Cat5e cable. Use one pair to these terminals and
then one wire from one of the other pairs to connect
terminal 6. If wiring will be outdoors or underground,
use Cat5e Gel Filled (flooded) UV Resistant Direct
Burial Cable. Match terminals on RS 485 board (i.e.,
term 6 to term 6; term 7 to term 7; term 8 to term 8).

1

2

3

4

5

6

7 8

9

0

SW2

OF
F

SW4

S

W3

1

2

3

4

5

6

7 8

9

0

SW

3

1

2

3

4

5

6

7 8

9

0

1

2

3

4

5

6

7 8

9

0

SW2

OF
F

SW4

1

Incorrect

ON

SW1

MODEM / TCP ENB

1

2

3

4

5

6

7

8

BAD DNS

RS-485 RX

LAN DOWN

Phone Line In

Use

L

AN Conn

ect

ion

Dat

a

T

ran

smi

t

To “Devices” 3-4-5-6;
addresses 005, 006, 007 , 008.

3

RS-485 Board

Terminal 1 from the 1838 RS-485 board connects to Device board(s) terminal 8.
Terminal 2 from the 1838 RS-485 board connects to Device board(s) terminal 7.
Terminal 3 from the 1838 RS-485 board connects to Device board(s) terminal 6.

Wires connecting terminals 1 & 2 to terminals 8 & 7 MUST be twisted.

Term 8
RS-485 Data A (+)

Term 6
RS-485 Common

Term 7
RS-485 Data B ( - )

Term 1

RS-485 Data A ( + )

Term 2

RS-485 Data B ( - )

Term 3

RS-485 Common

RS-485 Board

Device Board

RS-485 Terminal Connections

1 12-24 V AC/DC Input ( )
2 12-24 V AC/DC Input ( )

3 Relay Normally Open (N.O.)
4 Relay Normally Closed (N.C.)
5 Relay Common

6 RS485 Gnd
7 RS485 Data (B)
8 RS485 Data (A)

9 Request to Exit Com
10 Request to Exit Input

Device Board Terminals

NOTE:
“Devices” can be card
readers, keypads or RF
receivers

SW

3

SW2

SW

4

11

12

13

16 15 14

17

1

2

3

4

5

6

7

8

9

10

OFF

SW5

RS-485 Device Connections

DOORKING, INC., INGLEWOOD, CA 90301

Date:

Dwg. No.

Rev.

Title:

1/12

C

1838-003-C

3

SW2

ON

TERMINATION

OFF

AP Controller

OFF

Middle Unit

SW 2 OFF

ON

AP Controller

End Unit

SW 2 ON

8

If the AP Controller is an END unit, then SW 2 is ON. If the AP Controller is a middle unit,
then SW 2 is OFF.

8

Page 14

1838-066-D-1-12

Advertising