3 device access code programming, 4 delete device access codes – DoorKing 1838 Telephone Access Plus User Manual

Page 28

Advertising
background image

Page 28

1838-066-D-1-12

2.5.3 Device Access Code Programming

This programming sequence programs device (card readers, keypads, RF receivers, etc.) access
codes into the system memory with time zone restrictions applied. It also allows programming of the
device access codes to momentarily activate a relay or to hold (latch) a relay.

1. Press * 7 0 and enter the MASTER CODE. [ * 7 0 _ _ _ _ (beep)]

2. Enter the device type (0=card, 1=transmitter, 2=keypad, 3=other), then press *. [ _ * (beep)]

3. Enter the five-digit device access code then press *. [ _ _ _ _ _ * (beep)]

4. Enter a minimum of 1, and a maximum of 4 time zones (valid time zones are 0 through 6) that

you want to apply to this access code, then press *. [ _ _ _ _ * (beep)]
Time zone 0 is always deny access, time zone 1 allows 24/7 access for relay 1and any
additional relays; time zone 2 allows 24/7 access for relay 2 and any additional relays. Time
zones 3, 4, 5 and 6 are time zones that have been programmed in 2.6.3.

5. Enter 0 * for momentary relay activation or enter 1 * to hold (latch) the relay. [ _ * (beep)]

6. Repeat steps 2 through 5 to program additional device access codes.

7. Press 0# TOGETHER to end. [0# (beeeeeep)]

2.5.4 Delete Device Access Codes

This programming sequence deletes device access codes that have been programmed into the
system.

1. Press * 7 1 and enter the MASTER CODE. [ * 7 1 _ _ _ _ (beep)]

2. Enter the device type (0=card, 1=transmitter, 2=keypad, 3=other), then press *. [ _ * (beep)]

3. Enter the five-digit device access code to be deleted then press *. [ _ _ _ _ _ * (beep)]

4. Repeat steps 2 and 3 to delete additional device access code numbers.

5. Press 0# TOGETHER to end. [0# (beeeeeep)]

2.5.5 Delete All Device Access Codes (of the same type)

This programming sequence deletes all device access codes for the same type of device.

WARNING: Once started, all devices of a type will be erased.

1. Press * 7 2 and enter the MASTER CODE. [ * 7 2 _ _ _ _ (beep)]

2. Enter the device type (0=card, 1=transmitter, 2=keypad, 3=other), then press *. [ _ * (beep)]

3. Press 9 9 9 9 then press *. [ 9 9 9 9 * (beep)]

4. The programming sequence will end itself automatically. [beeeeeep]

Advertising