3 sub-net mask (reboot required), 5 set the port number (reboot required), Stop – DoorKing 1838 Telephone Access Plus User Manual

Page 22

Advertising
background image

Page 22

1838-066-D-1-12

2.3.3 Sub-Net Mask (reboot required)

Default value is: 255.255.255.000

All sub-net mask should be set to 255.255.255.000. If not, consult your network expert. Valid values
for any of the three digit numbers is 000 to 255.

1. Press * 5 2 and enter the MASTER CODE. [* 5 2 _ _ _ _ (beep)]

2. Enter the sub-net mask number. Use the * key to enter the “dot.”

[ _ _ _ * (beep) _ _ _ * (beep) _ _ _ * (beep) _ _ _ * (beep)]

3. Press 0 # TOGETHER to end. [0 # (beeeeeep)]

2.3.4 Set the Gateway (router) IP Address (reboot required)

Default value is: 192.168.001.001

If the 1838 is connected directly to the computer with a crossover cable, then this address must be
set to 000.000.000.000. If the 1838 is connected to the computer through a router, then set this value
to the router’s IP address. Valid value for any of the three digit numbers is 000 to 255.

1. Press * 5 3 and enter the MASTER CODE. [* 5 3 _ _ _ _ (beep)]

2. Enter the gateway (router) IP address. Use the * key to enter the “dot.”

[ _ _ _ * (beep) _ _ _ * (beep) _ _ _ * (beep) _ _ _ * (beep)]

3. Press 0 # TOGETHER to end. [0 # (beeeeeep)]

2.3.5 Set the Port Number (reboot required)

Default value is: 01030

This must be the same port number that was programmed in the software. Valid values are 01024 to
65535.

1. Press * 5 6 and enter the MASTER CODE. [* 5 6 _ _ _ _ (beep)]

2. Enter the port number, then press *. [ _ _ _ _ _ * (beep)]

3. Press 0 # TOGETHER to end. [0 # (beeeeeep)]

STOP!

If you are using a computer with the 1838 Access Plus, no other programming at the keypad is
required. All programming parameters beyond this point can be set in the Management
software.