SECTION 3 – USER INSTRUCTIONS

LED Status Indicators

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

Master

Code

ON

SW1

MODEM / TCP ENB

1

2

3

4

5

6

7

8

BAD DNS

RS-485 RX

LAN DOWN

Phone Line

In Use

LA

N

C

o

n

n

ect

io

n

Da

ta

Tr

a

ns

m

it

SW2

ON

TERMINATION

OFF

Master Code
Push Button

Master Code
LED

Keypad

1838-066-D-1-12

Page

35

Master Code

Blink

OV (Over Voltage)

ON when input voltage (16 VAC) is too high. Board automatically shuts down.

RS-485 RX

Green LED indicates that the system is on-line and scanning the RS-485 devices.

BAD DNS

Yellow LED indicates an email server problem, rejecting the mail server.

LAN DOWN

Red LED indicates a problem with the LAN. IP or Gateway (router) down or wrong gateway IP
address.

Phone Line In Use

Yellow LED indicates that the phone line is being used (dial-out, call forwarding, etc.)

LAN Connection

Green LED indicates that the wire connection from the 1812 to the computer or router is good.

DATA Transmit

Yellow LED indicates that the TCP / IP connection is transmitting data or sending an email.

SW1 - Modem TCP Enable

This switch should be in the ON position. Turning SW1 Off will reset the TCP/IP connection and
should be used for troubleshooting purposes only.

SW2 - Termination

If the 1838 Access Plus Controller is an END unit, then SW 2 is ON. If the 1838 Access Plus
Controller is a middle unit, then SW 2 is OFF.

1 2 3 4 5 6 7 8 9 1011

OV