Advanced set-up mode over view, Ph 300 meter set up mode, Ph 310 meter set up mode – Nova-Tech pH 310 User Manual

Page 14: P3.0: v iewing electrode data, P2.0: v iewing previous calibration data, P4.0: unit configuration, P5.0: reset to factory default, P6.0: reset to factory default, P5.0: setting clock

Advertising
background image

pH 300 meter set up mode

27

26

Advanced set-up mode over

view

P3.0: V

iewing electrode data

In pH measur

ement mode:

• P3.1: pH electr

ode of

fset

• P3.2: pH electr

ode slope

In mV (or r

elative mV) measur

ement mode:

•

P3.1: r

elative mV of

fset

P1.0: Memory clear

• P1.0 Clear all stor

ed r

eadings

P2.0: V

iewing previous calibration data

• P2.1: First calibration point

• P2.2: Second calibration point

• P2.3: Thir

d calibration point

• P2.4: Fourth calibration point

• P2.5: Fifth calibration point

Instructions on page 28

Instructions on page 36

Instructions on page 29

8.1

Instructions on page 30-31

P4.0: Unit configuration

•

P4.1: Ready indicator on or of

f

• P4.2: # of calibration points: 2, 3, 4, or 5

P5.0: Reset to factory default

•

P5.0: Reset to factory default settings

Instructions on pages 32-33

SETUP

MEM

pH

SETUP

pH

SETUP

SETUP

MEAS

SETUP

Pr

ess the SETUP

key to enter Set up mode.

Pr

ess the

▲
and

▼
keys to scr

oll thr

ough sub gr

oups.

MEAS

SETUP

SETUP

pH 310 meter set up mode

P3.0: V

iewing electrode data

In pH measur

ement mode:

• P3.1: pH electr

ode of

fset

• P3.2: pH electr

ode slope

In mV (or r

elative mV) measur

ement mode:

•

P3.1: r

elative mV of

fset

P1.0: Memory clear

• P1.0 Clear all stor

ed r

eadings

P2.0: V

iewing previous calibration data

• P2.1: First calibration point (plus time/date)

• P2.2: Second calibration point (plus time/date)

• P2.3: Thir

d calibration point (plus time/date)

• P2.4: Fourth calibration point (plus time/date)

• P2.5: Fifth calibration point (plus time/date)

• P2.6:

Sixth calibration point (plus time/date)-only

available when DIN buf

fer set is selected in P4.3

Instructions on page 28

Instructions on page 39

Instructions on page 29

Instructions on page 30-31

P4.0: Unit configuration

•

P4.1: Ready indicator on or of

f

•

P4.2: # of calibration points: 2, 3, 4, 5, or 6 (6th point

available for DIN

buf
fer set only)

• P4.3: Select calibration buf

fer set: USA, DIN, or NIST

• P4.4: Select °C or °F

P6.0: Reset to factory default

•

P6.0: Reset to factory default settings

Instructions on pages 32-35

Instructions on pages 37-38

SETUP

MEM

pH

SETUP

pH

SETUP

SETUP

P5.0: Setting Clock

• Setting

year

• Setting date (month/day)

• Setting time (hour/minute/second)

http://www.novatech-usa.com/Products/Laboratory-Equipment-Supply-Products Tel: (281) 359-8538 Toll Free:(86

6) 433-6682