PASCO Xplorer-GLX Users’ Guide User Manual

Page 130

Advertising
background image

124

V o l t a g e v e r s u s R e s i s t a n c e

2.

Lay out the circuit on a piece of paper so you can label the parts of the cir-
cuit. Label points A through F and the positive and negative terminals of the
battery.

GLX Set-Up

1.

Connect the voltage probe to the GLX.

a)

Connect the voltage probe to the voltage port on the left side of the

GLX.

b)

If there are other sensors connected to the GLX, remove them.

2.

Configure the GLX for manual sampling.

a)

Press

to return to the Home Screen; press

to open the Sensors

screen.

b)

Press

to open the Mode menu; press

to select Manual.

The Data Properties dialog box for the manually entered resistance data

will open.

c)

With Measurement Name highlighted, press

; type “r” and press

.

d)

Press the down arrow key to highlight Measurement Unit. Press

,

type “ohm”, and press

.

e)

Press

to approve these data properties and close the Data Proper-

ties window.

3.

Prepare the Graph to plot voltage versus resistance.

a)

Press

to return to the Home Screen; press

to open the Graph.

The Graph will be automatically set up for voltage versus time. In the

next step, you will select resistance (instead of time) for the horizontal

axis.

b)

Press

to turn on the highlight; press the down arrow key to high-

light “Time.”

c)

Press

to open the data source menu.

d)

In the data source menu, use the arrow keys to highlight “r” and press

.

F4

F1

F1

2

tuv

Enter the

Measurement Name

and Unit.

F2

F1

F1

F1

Select resistance for the

horizontal axis