F4 graphs menu – PASCO Xplorer-GLX Users’ Guide User Manual

Page 28

Advertising
background image

22 G r a p h

and other tools are applied. In cases where the two data sets are scaled separately,
the active that is scaled.

To toggle data without opening the menu: hold

, press

, and release both

keys.

Create Calculation from Linear Fit

This option appears in the Tools menu

when the Linear Fit (see page 19) is turned on. Select this option to automatically
create an equation in the calculator based on the slope and y-intercept of the cur-
rently display best-fit line. If the equation of the best fit line is

,

where m is the slope and b is the y-intercept, then the calculation will take the
form

. This calculation will appear in the Calculator and in

data source menus with the name “Linear Fit Cal.” For instructions on working
with calculations, see page 41.

F4 Graphs Menu

The Graphs menu contains options

8

to control the appearance of the Graph, make

it emulate an oscilloscope, make it plot two data sets simultaneously, manage
multiple pages, and print.

Data Cursor

Select this option to turn on or off the Data Cursor and Coordi-

nates displayed on the Graph. See page 16 for more information.

Connected Lines

Select this option from the Graphs menu to turn on or off the

lines connecting the data points.

Graph with connected lines (left) and without connected lines (right)

Scope Mode

Select Scope mode from the Graphs menu to make the GLX emu-

late a digital storage oscilloscope. In this mode, the GLX collects and displays
data in repeated bursts. The length of the burst and the sample rate are deter-
mined by the time scale of the Graph display. Scope mode can be used with any
sensor to collect bursts of data; it is especially useful with the GLX’s built-in
sound sensor (see page 58) or voltage sensor.

When you turn on Scope mode, the Graph automatically sets its time range to
30 milliseconds and turns on the Trigger.

9

It also adjusts the sampling rate of the

displayed sensor so that it will collect about 500 data points (or as many as possi-
ble) in each burst. If you change the Graph’s time scale,

10

the GLX automatically

adjusts the sampling rate.

+

Toggle Data Shortcut

Esc

Esc

y

mx

b

+

=

x

1 m

(

)y b m

=

8

To select an option from the Graphs

menu

Keypad
1. Press

t

o open the Graphs

menu.

2. Use the arrow keys to move the high-

light to the desired menu option and
press ;

or press the number on the

keypad corresponding to the desired
menu option.

Mouse
1. Click “Graphs” at the bottom of the

screen to open the Graphs menu.

2. Click the desired menu option.

F4

The Graphs menu

Scope mode

9

The Trigger is initially disabled. See

page 20 for instructions on enabling and
setting the Trigger.

10

See “F1 Autoscale” and “F2 Scale/

Move” on page 16.

Advertising