94
AC/DC Electronics Laboratory
012-05892A
®
PROCEDURE
PART I: Computer Setup
➀
Connect the Science Workshop interface to the computer, turn on the interface, and turn on the
computer.
➁
Connect one Voltage Sensor to Analog Channel A. Connect the other Voltage Sensor to Analog
Channel B.
➂
Connect the Power Amplifier to Analog Channel C. Plug the power cord into the back of the
Power Amplifier and connect the power cord to an appropriate electrical receptacle.
➃
In the Physics Folder of the Science Workshop Experiment Library, open the document:
Macintosh: “P55 Transistor Lab 2” / Windows: “P55_TRN2.SWS”
The document opens with a Graph display of Output Current (mA) for Analog Channel B versus
Input Current (mA) for Analog Channel A, and the Signal Generator window which controls the
Power Amplifier (Analog Output).