Mechanical installation – standard models, Installation, Figure 8 figure 9 figure 10 – Alliance Laundry Systems UF250PV Tilt User Manual

Page 24

Advertising
background image

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Installation

F232102

22

Mechanical Installation – Standard
Models

Mounting Bolt Installation for Standard
135 Pound Capacity and 250 Pound
Capacity Machines

High-strength 3/4-16 x 10 in. machinery anchors should
be embedded in 3500 psi reinforced concrete that is a
minimum of 6 in. thick. Refer to Figure 8 for the
mounting bolt layout for standard 135 pound capacity
models. Refer to Figure 9 for the mounting bolt layout
for standard 250 pound capacity models. (The front of
the washer-extractor is the bottom of the diagram.)
Refer to Figure 10 for detailed information regarding
the machinery anchor bolt that should be used.

Figure 8

Figure 9

Figure 10

CFS213N

135

56 in.

(1422 mm)

3 in.

(76 mm)

3 in.

(76 mm)

66.63 in.

(1691 mm)

1.25 in.TYP

(32 mm)

62 in.

(1575 mm)

61 in.

(1549 mm)

12.81 in.

(324 mm)

36 in.

(914 mm)

12.31 in.

(311 mm)

CFS214N

CFS215N

1

Locknut

2

Base Frame

3

3/4-16 x 10 in. Dia. Bolt

4

Grout

5

Anchor Bolt

250

66 in.

(1676 mm)

3 in.

(76 mm)

3 in.

(76 mm)

19.5 in.

(495 mm)

40.69 in.

(1034 mm)

20 in.

(508 mm)

77.5 in.

(1969 mm)

1.25 in. TYP

(32 mm)

72 in.

(1829 mm)

80 in.

(2037 mm)

2

1

3

4

MOUNTING BOLT DETAIL – STANDARD MODELS

6 in.

(152 mm)

5

6 in.

(152 mm)

MIN

Advertising