Monthly preventive maintenance checklist – Alliance Laundry Systems UF250PV Tilt User Manual

Page 47

Advertising
background image

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Maintenance

45

F232102

Monthly Preventive Maintenance
Checklist

Machine

____________________________

Operator

___________________________

Month

Checks

Observe All Safety Warnings!

Disconnect power to the machine before performing the monthly maintenance procedures.

1. Each month OR every 200 hours of operation, lubricate the bearings and seals.

(Locate the bearing lubrication decal behind the external supply unit on the top right
of the machine.)

2. Clean the AC drive fins.

3. Determine if V-belts require replacement or adjustment:

a. Check V-belts for uneven wear and frayed edges.

b. Verify that V-belts are properly tensioned.

c. Verify that V-belts are properly aligned.

4. Remove back panel and check hoses for leaks.

5. Clean inlet hose filter screen. Replace if worn or damaged.

6. Tighten motor mounting bolt locknuts, bearing bolt locknuts, and idler pulley, if

necessary.

7. Use compressed air to clean lint from motor.

8. Clean interior of machine, both basket and shell, by wiping with a water-soaked

sponge or cloth.

9. Use compressed air to clean moisture and dust from all electrical components.