Installation

35

F232102

Chemical Injection Supply System

Undiluted chemical dripping can damage the washer-
extractor. Therefore, all chemical supply dispenser
pumps should be mounted below the washer’s
injection point. All dispenser tubing should also run
below the injection point. Loops do not prevent drips if
these instructions are not followed. Failure to follow
these instructions could damage the machine and void
the warranty. Refer to Figure 19 for a typical chemical
supply injection system on 135 pound capacity
models. Refer to Figure 20 for a typical chemical
injection supply system on 250 pound capacity
models.

Figure 19

Figure 20

Wear eye and hand protection when
handling chemicals; always avoid direct
contact with raw chemicals. Read the
manufacturer’s directions for accidental
contact before handling chemicals.
Ensure an eye-rinse facility and an
emergency shower are within easy reach.
Check at regular intervals for chemical
leaks.

WARNING

U087I

1

Chemical Dispenser Pump Outlet

3

PVC Pipe

2

Supply Dispenser

U087I

2

1

3

TYPICAL INJECTION SYSTEM FOR 135 POUND CAPACITY MODELS

R010I

1

Chemical Dispenser Pump Outlet

3

PVC Pipe

2

Supply Dispenser

R010I

2

1

3

TYPICAL INJECTION SYSTEM FOR 250 POUND CAPACITY MODELS