Installation

F232102

34

Steam Requirements
(Steam Heat Option Only)

For washer-extractors equipped with optional steam
heat, install piping in accordance with approved
commercial steam practices. Steam requirements are
shown in Table 7.

NOTE: Failure to install the supplied steam filter
may void the warranty.

Air Requirements

Air supply requirements are shown Table 8, Table 9
and Table 10.

Cabinet Freestanding

Steam Supply Information

135

250

Steam inlet connection

3/4 in.

(DN20)

(19.05 mm)

1 in. (DN25)

(25.4 mm)

Number of steam inlets

1

1

Recommended pressure

30 – 80 psi

(2.0 – 5.5 bar)

30 – 80 psi

(2.0 – 5.5 bar)

Maximum pressure

80 psi

(5.4 bar)

80 psi

(5.4 bar)

Table 7

Never touch internal or external steam
pipes, connections, or components.
These surfaces can be extremely hot and
will cause severe burns. The steam must
be turned off and the pipe, connections,
and components allowed to cool before
the pipe can be touched.

SW014

WARNING

Standard 135 Pound Cabinet Freestanding

Air Supply Information

Inlet size

1/4 in. (DN8)

(6.35 mm)

Recommended pressure

25 – 100 psi
(1.7 – 8 bar)

Average consumption

0.1 CFM

(.003 CMM)

Table 8

Standard 250 Pound Cabinet Freestanding

Air Supply Information

Inlet size

1/4 in. (DN8)

(6.35 mm)

Recommended pressure

25 – 100 psi
(1.7 – 8 bar)

Average consumption

0.1 CFM

(.003 CMM)

Table 9

250 Pound Cabinet Freestanding with Tilt Air

Supply Information

Inlet size

1/4 in. (DN8)

(6.35 mm)

Recommended pressure

80 – 100 psi

(5.5 – 6.9 bar)

Average consumption

1.5 CF/tilt

(.05 CM/tilt)

Table 10