Installation

37

F232102

Any injection system pump which requires 110VAC
must be powered by a separate external power source.

Consult the Chemical Injection Supply System
instructions for operational details.

Figure 22

250 Pound Capacity Models

On 250 pound capacity models, the external supply
terminal strip is located in the rear control module, on
the left side. Refer to Figure 23 for an example of the
decal applicable to 250 pound capacity models.

Terminals SUPPLY 1 through SUPPLY 5 provide
100 – 120VAC fused at 500mA.

These terminals may be used to provide signals to the
chemical injection system but must not be used to
provide power to the pump. Do not attempt to increase
fuse rating as this may cause damage to the washer-
extractor’s circuitry.

An external chemical injection system requiring
200 – 240VAC can be powered through LINE 1 and
LINE 2 on the external supply terminal strip on PVQ
and PVT models. Any chemical injection system used
with PVM, PVN, and PVP models must be powered
by a separate independent power source.

Figure 23

U078I

Attempting to obtain 110VAC by using L1
or L2 with the common may damage
laundry machine circuitry and/or the
chemical injection system. Using a
240VAC power wire in the washer-
extractor and an earth ground to obtain
110VAC could cause microprocessor
problems.

SW028

CAUTION

F3A

F10A MAX

LINE 1

LINE 2

SUPPLY 1

SUPPLY 2

SUPPLY 3

SUPPLY 4

SUPPLY 5

SUPPLY 1

SUPPLY 2

SUPPLY 3

SUPPLY 4

SUPPLY 5

PVM, PVN, AND PVP MODELS

PVQ AND PVT MODELS

135 POUND CAPACITY MODELS

u079i

Attempting to obtain 110VAC by using L1
or L2 with the common may damage
laundry machine circuitry and/or the
chemical injection system. Using a
240VAC power wire in the washer-
extractor and an earth ground to obtain
110VAC could cause microprocessor
problems.

SW028

CAUTION

EXTERNAL SUPPLIES

CAGE CLAMP TERMINAL

ALL SUPPLY SIGNAL CONNECTIONS

120 V.A.C. 05 A MAX. 16-24 AWG

CAGE-CLAMP MUST BE PRESSED DOWN

AS SHOWN TO INSERT OR REMOVE WIRES

NEUTRAL

SUPPLY 1

SUPPLY 2

SUPPLY 3

SUPPLY 4

SUPPLY 5

SCREWDRIVER

WARNING

250 POUND CAPACITY MODELS