INSTALLATION

FTA-IOM-2013-0227

SECTION 2

2-18

!

WARNING

All information in this manual is for
reference and guidance purposes,
and does not substitute for required
professional training, conduct,
and strict adherence to applicable
jurisdictional/professional codes and
regulations.

Non-Fulton product information is for
reference purposes only. No Fulton
document may substitute for full
review of documentation available
from the component manufacturer.

TABLE 5 - RECOMMENDED GASKET LOADS FOR FLEXITALLIC SPIRAL WOUND CLASS 150#

GASKETS SAE GRADE 5 BOLTS OR EQUAL

Nominal Flange

Size (in.)

Number of Bolts

Diameter of Bolts

(in.)

Preferred Torque

Req. Per Bolt (ft-lb)

1/2

4

1/2

45

3/4

4

1/2

45

1

4

1/2

45

1 1/4

4

1/2

45

1 1/2

4

1/2

45

2

4

5/8

90

2 1/2

4

5/8

90

3

4

5/8

90

3 1/2

8

5/8

90

4

8

5/8

90

5

8

3/4

150

6

8

3/4

150

8

8

3/4

150

10

12

7/8

240

TABLE 6 - RECOMMENDED LOADS FOR FLEXITALLIC SPIRAL WOUND CLASS 300# GASKETS

SAE GRADE 5 BOLTS OR EQUAL

Nominal Flange

Size (in.)

Number of Bolts

Diameter of Bolts

(in.)

Preferred Torque

Req. Per Bolt (ft-lb)

1/2

4

1/2

45

3/4

4

5/8

90

1

4

5/8

90

1 1/4

4

5/8

90

1 1/2

4

3/4

150

2

8

5/8

90

2 1/2

8

3/4

150

3

8

3/4

150

3 1/2

8

3/4

150

4

8

3/4

150

5

8

3/4

150

6

12

3/4

150

8

12

7/8

240

10

16

1

368