INSTALLATION

FTA-IOM-2013-0227

SECTION 2

2-20

!

WARNING

All information in this manual is for
reference and guidance purposes,
and does not substitute for required
professional training, conduct,
and strict adherence to applicable
jurisdictional/professional codes and
regulations.

Non-Fulton product information is for
reference purposes only. No Fulton
document may substitute for full
review of documentation available
from the component manufacturer.

To maintain a reasonable
temperature in the equipment area
and ensure safety to personnel, the
section of the chimney duct within
the building should be insulated.

Due to extremely high operating
temperatures of the thermal fl uid,
all exposed pipework should be
insulated, and exposed hot fl anges,
pump, valve, and fi ttings should be
shielded. Refer to Insulation section of
this manual for details.

Insulation

After the appropriate system tests have been satisfactorily completed
(see Testing section of this manual), all hot pipework and vessels must be
adequately insulated with material suited to the temperature and application
to prevent both heat loss and personnel injury.

Adhere to the following for insulation installation:

1. For inspection and maintenance purposes, leave pumps, fl anges, valves

and fi ttings uninsulated but suitably shielded for safety.

2. Insulate the deaerator section of the combination tank.

3. Do not insulate the thermal buff er and expansion sections of the

combination tank. On units operated with inert gas blankets above the
fl uid in the expansion tank, the entire combination tank, including the
expansion and thermal buff er sections, may be insulated but it is not
necessary.

4. Ensure hot oil pipe insulation is a minimum of 2” (51 mm) thick,

high temperature, laminated, foamglass cellular glass insulation as
manufactured by Pittsburgh Corning Corporation or equal.

System Interfaces

Proper selection and installation of the components in the hot oil system will
ensure proper and safe operation of the heater.

Heater Connections

Adhere to the following for heater connections:

1. Connect the outlet of the pump directly to the inlet of the heater via

an isolating valve (preferably a throttling valve) and pump fl exible
connector.

2. Pipe heater outlets directly to the system via an isolating valve.

3. A safety relief valve may be shipped in the parts box accompanying

the fuel-fi red heater, and must be installed in the outlet manifold. On
all units, the outlet must be piped to a safe discharge area. The piping
from the outlet of the safety valve must be piped to a catch tank. The
discharge fl ow must not be restricted, i.e. no valve should be installed.
The weight of the piping must be properly supported in order to prevent
damage to the safety valve. If the valve body becomes warped, leakage
may result.

Thermal Fluid Circulating Pump

Installing the pump in accordance with the manufacturer’s specifi cations
and these instructions will prolong the life of the pump and contribute
signifi cantly to the successful operation of your Fulton heater system. The