TABLE 7 - RECOMMENDED LOADS FOR JM CLIPPER ELASTOGRAPH 150# GASKETS SAE

GRADE 5 BOLTS OR EQUAL

Nominal Flange

Size (in.)

Number of Bolts

Diameter of Bolts

(in.)

Preferred Torque

Req. Per Bolt (ft-lb)

1/2

4

1/2

30

3/4

4

1/2

30

1

4

1/2

30

1 1/4

4

1/2

30

1 1/2

4

1/2

30

2

4

5/8

60

2 1/2

4

5/8

60

3

4

5/8

60

4

8

5/8

60

5

8

3/4

100

6

8

3/4

100

8

8

3/4

100

10

12

7/8

160

TABLE 8 - RECOMMENDED LOADS FOR JM CLIPPER ELASTOGRAPH 300# GASKETS SAE

GRADE 5 BOLTS OR EQUAL

Nominal Flange

Size (in.)

Number of Bolts

Diameter of Bolts

(in.)

Preferred Torque

Req. Per Bolt (ft-lb)

1/2

4

1/2

30

3/4

4

5/8

60

1

4

5/8

60

1 1/4

4

5/8

60

1 1/2

4

3/4

100

2

8

5/8

60

2 1/2

8

3/4

100

3

8

3/4

100

4

8

3/4

100

5

8

3/4

100

6

12

3/4

160

8

12

7/8

245

10

16

1

160