6. When you make your selection, the

alarm number is displayed in the second
line. The alarm parameters are listed on
the screen. Use the

UP

and

DOWN

keys

to scroll through the values within each
alarm parameter. Press

SELEC

to select

the desired parameters. Press

ACCPT

to

enter all of the selected values into the
computer. These are now the set values
for this particular alarm.

Fail-safe option YES de-activates the alarm relay on the rear panel
(TB1, TB2, TB3, TB4 or TB5 for alarms 1 through 5) when an
alarm condition exists, including system power failure. If NO is
chosen, the relay will allow activation of the alarms during alarm
status.
Note that an external alarm in series with a power supply should be
connected across the C and NC (normally closed) relay contacts in
fail-safe mode, and across the C and NO (normally open) contacts in
non-fail-safe mode.

Level indicates the oxygen level that will activate the alarm.

High/Low indicates whether the level is a high- or low-threshold.

Latching option YES means that the alarm will continue to ring
after being triggered by an alarm status, even though the oxygen has
returned to acceptable levels. The ALRMR button on the keyboard
in the Analyze mode menu must be pressed to end the alarm.

Defeat option YES renders the alarm inoperative.

7. When you press

ACCPT

, the next screen

allows you to select another alarm to set
up. You can select another alarm (up to
5 alarms), or press

ESC

twice to return

to the Analyze mode.

8. Pressing

ESC

twice returns you to the

Analyze mode main menu. The appro-
priate alarm number and type flashes in
the upper right-hand corner of the
display if the alarm is tripped.

VALVES: ANALYZE C=9:59

T=25C

ALARM 1 SETUP

LEVEL = 1.00 PPM RELAY =TB1
HIG H/LO W HI FAILSAFE YES
LATCHING NO DEFEAT NO

1

2

3

4

5

ESC

UP

SELEC

DOW N

ACCPT

VALVES: ANALYZE

T=25C

C =9:59

A LA R M S SETU P
SELEC T A LA R M TO SETU P

1

2

3

4

5

A L 2

A L 1

M O R E

ESC

VALVES: ANALYZE

T=25C

C=9:59

FLOW = 150.0 CC/M IN

AUTORANGE: 10 PPM

1

2

3

4

5

RANGE

ALRM R

5.00

PPM 02

ALRM 1-HI

SETUP

STDBY

CAL