Plc / axis unit bank data – FEC AFC1100 User Manual

Page 13

Advertising
background image

)(& ,QF

4.7.4 Bank Select Table

See Work 0 ,1

WORK 2

DATA 7

Output when Fastening resulted in a Torque
Low Reject.

TORQUE LOW

REJECT

DATA 6

Output when Fastening resulted in a Torque
High Reject.

TORQUE HIGH

REJECT

DATA 5

Output when Fastening resulted in a Final
Time Reject.

FINAL TIME

OVER REJECT

DATA 4

Output when Fastening resulted in a 1st
Time Reject.

1ST TIME

OVER REJECT

DATA 3

not used

METHOD 2

DATA 2

not used

METHOD 1

DATA 1

Outputs when the fastening method is Angle
control.

METHOD 0

DATA 0

ON

OFF

2

Output when the spindle is bypass either via
the PLC input or the Axis Unit front panel
switch.

BYPASS

DATA 7

WORK 1

DATA 6

Output confirmation of WORK SELECT 0~2
(Pins 14~16) input selections.

WORK 0

DATA 5

Output after a START signal is received, and
active until the fastening cycle is complete
and the READY signal is output.

BUSY

DATA 4

Output when the system is in READY
condition. Indicates system is ready to
operate, and inputs are enabled. This signal
is inactive (off) when the BUSY output is
active (on).

READY

DATA 3

Output when an Abnormal condition occurs,
this signal indicates that the System has
detected an internal fault, and can no longer
proceed. An Abnormal condition must be
corrected before the System will resume
normal operation.

ABNORMAL

DATA 2

Output when the fastening result is a
ACCEPT. Indicates that the spindle is within
the fastening limits. This output remains
active until the START signal or RESET
signal is input.

ACCEPT

DATA 1

Output when the fastening result is a
REJECT. Indicates that the spindle has
failed the fastening limits. This output
remains active until the START signal or
RESET signal is input.

REJECT

DATA 0

OFF

OFF

1

DESCRIPTION

NAME OF

SIGNAL

BANK DATA

PINS 25 ~ 18

0

PIN 13

1

PIN12

BANK

#

PLC / AXIS UNIT BANK DATA

BANK

SELECT

INPUT

Chapter 4: System Setup and Wiring (Rev. 8/98)

Page 4-13