4.9 Torque/Angle OUT (external monitoring connector).

This connector outputs a torque voltage and an angle digital pulse signal.

{ Adapter plug description:

P Manufacturer: Molex.

P Type: Socket receptacle.

P Model: 5557-04R, 5556* (*depending on the wire

dimensions).

Currently Molex 5569-04A1 Axis unit connector.

FIG. 4-9a T/A OUT connector

Forward/Reverse pulse monitoring output. TTL, IOL = 30 ma.

OUT

Motor rotation

Monitoring signal output ground.

Ground

Torque voltage monitoring output. Full scale torque = 2.5 V

OUT

Torque

Angle pulses monitoring output. TTL, IOL = 30 ma.

OUT

Angle pulses

Description

IN/OUT

Signal

Pin

IOL = Current Output Low

{ Torque Voltage.

Analog voltage signal will show 2.5V variation from zero to full scale torque.

{ Angle pulses.

TTL signal (0V to 5V). 1 degree equals 1 pulse.

{ Motor rotation.

TTL signal (0V to 5V). The signal will be LOW to indicate Forward rotation and will be HIGH
to indicate Reverse rotation.