4.7.5 PLC Wiring Sample

This diagram represents standard I/O connections. For the SYNC signal connection method,
Please refer to section 4.7.6: Synchronized Fastening Operation.

FIG. 4-7-5 PLC Wiring Sample

All AFC1100 inputs and outputs (I/O) are active true low. All interface devices must
accommodate active true low logic for correct operation. Outputs are rated at +12~24 VDC,
200mA. When activated, open collector sink outputs (normally high) pull the input device
signal low (0 VDC). Inputs are sourced (normally high) and activated when pulled low
(0 VDC).