FIG. 4-10-3 Ramp-Up Time Dip Switches

The dip switches are set by the factory to 250 milliseconds, and the maximum possible
duration is 500 milliseconds. Available ramp-up times and the appropriate dip switch settings
are given in the table below. Setting the switches in any other combination will result in an
erroneous setup.

OFF

OFF

ON

ON

.10 SECOND

OFF

ON

OFF

ON

.25 SECOND

ON

OFF

OFF

ON

.50 SECOND

OFF

OFF

OFF

ON

1.0 SECOND

500 msec

250 msec

100 msec

0 msec

RAMP-UP
DURATION

4.10.3 Ramp-Up Time Setup

The ramp-up time dip switches control the duration of the initial tool speed ramp-up. If the
duration is too short, the tool starting inertia may be falsely sensed by the System as a torque
reading. If the duration is too long, the extended cycle time will result in reduced System
efficiency.