)(& ,QF

SV ERROR 2

DATA 7

SV ERROR 1

DATA 6

Outputs a detailed code when a SV AMP
ERR is output. Error code is output in three
bits. (See Section 4.7.3 ).

SV ERROR 0

DATA 5

Outputs when a servo abnormality occurs,
see SV ERR 0~2 codes below.

SV AMP ERR

DATA 4

Outputs when a tool related abnormality
occurs.

TOOL ERR

DATA 3

Outputs when an abnormal condition occurs
in the encoder.

ENC ERR

DATA 2

Outputs when an abnormal condition occurs
in the parameter setting.

PSET ERR.

DATA 1

Outputs when an abnormal condition occurs
during the SELF CHECK (CAL and Zero).

ZERO CAL
ERR

DATA 0

ON

ON

4

not used

DATA 7

not used

DATA 6

Output when Fastening resulted in a 2nd
Torque Rate Low Reject.

2ND RATE

LOW REJECT

DATA 5

Output when Fastening resulted in a 2nd
Torque Rate High Reject.

2ND RATE

HIGH REJECT

DATA 4

Output when Fastening resulted in a 1st
Torque Rate Low Reject.

1ST RATE

LOW REJECT

DATA 3

Output when Fastening resulted in a 1st
Torque Rate High Reject.

1ST RATE

HIGH REJECT

DATA 2

Output when Fastening resulted in an Angle
Low Reject.

ANGLE LOW

REJECT

DATA 1

Output when Fastening resulted in an Angle
High Reject.

ANGLE HIGH

REJECT

DATA 0

OFF

ON

3

DESCRIPTION

NAME OF

SIGNAL

BANK DATA

PINS 25 ~ 18

0

PIN 13

1

PIN12

BANK

#

PLC / AXIS UNIT BANK DATA

BANK

SELECT

INPUT

Chapter 4: System Setup and Wiring (Rev. 8/98)

Page 4-14