Checking detail elevation – Fairbanks 6020 Series Titan Motor Truck Scale User Manual

Page 13

Advertising
background image

d.

On the bottom of the load cells there are two flatsides which must be aligned
with the flats in the lower cup. Carefully lower the scale while seating the
bottom of the cell into the lower cup. Check the scale's level and height,
particularly at the approaches. Use the load cell shims provided to adjust load
cell cups for correct height and to ensure that all cells share the proper amount
of load. Center section cells will have up to twice the deadload of end section
cells.

e.

When the modules are level and at the correct height, tighten the module-to-
module bolts.

The bolts should be torqued to 500 ft lbs.

f.

Load cell cables:

Route the load cell cables to the conduits that go through the scale and
also over the top of the module diaphram plates. Coil excess cables on the
cable hanger on the interior side of the I-beams (see Image 50745-11).

9.

Final Checking Adjustment:

a.

Adjust End Checking

Adjust the End Checking Bolts to allow

1

/

16

” to

1

/

8

” clearance.

b.

Adjust side checking bolts to allow

1

/

16

” clearance from block.

50745

13

03/10 Rev. 5

SIDE CHECK

BRACKET

CHECKING DETAIL ELEVATION

3/4-10 X 3" FULL THD

BOLTS, PART # 54559,

(6) REQ'D EACH

END WALL

BASE PLATE

4' 7-3/8”

10-5/8"

3-1/8"

REF

1'-9”

CABLE HANGER

CABLE HOLE

5’-6”

LOAD CELL

50745-11

Advertising